{"id":681,"date":"2024-03-05T13:30:10","date_gmt":"2024-03-05T12:30:10","guid":{"rendered":"https:\/\/www.optimalcomputing.be\/wordpress\/?p=681"},"modified":"2024-03-13T21:45:21","modified_gmt":"2024-03-13T20:45:21","slug":"pump-optimization","status":"publish","type":"post","link":"https:\/\/www.optimalcomputing.be\/index.php\/2024\/03\/05\/pump-optimization\/%20","title":{"rendered":"Pump Optimization"},"content":{"rendered":"\n<div class=\"wp-block-group alignfull is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:0px;margin-bottom:0px;padding-top:64px;padding-bottom:64px\">\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<h2 class=\"wp-block-heading\">Pump Multi-Disciplinary Optimization<\/h2>\n\n\n\n<p class=\"has-normal-font-size\">In this application, the goal is to perform the optimization of a radial pump. The goal is to modify 13 parameters of the geometry to increase the pump&nbsp;<strong>efficiency<\/strong>&nbsp;while keeping the&nbsp;<strong>mechanical stresses<\/strong>&nbsp;below a maximum value and using constraints on the&nbsp;<strong>mechanical vibration mode<\/strong>&nbsp;of the pump.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"1522\" height=\"1551\" src=\"https:\/\/www.optimalcomputing.be\/\/wp-content\/uploads\/2024\/03\/Initial_Optimized_3D_3.png\" alt=\"\" class=\"wp-image-685\" style=\"border-width:2px;border-radius:30px;width:294px;height:auto\" srcset=\"https:\/\/www.optimalcomputing.be\/wp-content\/uploads\/2024\/03\/Initial_Optimized_3D_3.png 1522w, https:\/\/www.optimalcomputing.be\/wp-content\/uploads\/2024\/03\/Initial_Optimized_3D_3-294x300.png 294w, https:\/\/www.optimalcomputing.be\/wp-content\/uploads\/2024\/03\/Initial_Optimized_3D_3-1005x1024.png 1005w, https:\/\/www.optimalcomputing.be\/wp-content\/uploads\/2024\/03\/Initial_Optimized_3D_3-768x783.png 768w, https:\/\/www.optimalcomputing.be\/wp-content\/uploads\/2024\/03\/Initial_Optimized_3D_3-1507x1536.png 1507w\" sizes=\"auto, (max-width: 1522px) 100vw, 1522px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"717\" height=\"627\" src=\"https:\/\/www.optimalcomputing.be\/\/wp-content\/uploads\/2024\/03\/pompe.png\" alt=\"\" class=\"wp-image-1036\" style=\"border-width:2px;border-radius:30px;width:345px;height:auto\" srcset=\"https:\/\/www.optimalcomputing.be\/wp-content\/uploads\/2024\/03\/pompe.png 717w, https:\/\/www.optimalcomputing.be\/wp-content\/uploads\/2024\/03\/pompe-300x262.png 300w\" sizes=\"auto, (max-width: 717px) 100vw, 717px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image aligncenter size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"755\" height=\"397\" src=\"https:\/\/www.optimalcomputing.be\/\/wp-content\/uploads\/2024\/03\/OptimizationConvergenceEfficiencyVonMises.jpg\" alt=\"\" class=\"wp-image-687\" style=\"border-width:2px;border-radius:30px\" srcset=\"https:\/\/www.optimalcomputing.be\/wp-content\/uploads\/2024\/03\/OptimizationConvergenceEfficiencyVonMises.jpg 755w, https:\/\/www.optimalcomputing.be\/wp-content\/uploads\/2024\/03\/OptimizationConvergenceEfficiencyVonMises-300x158.jpg 300w\" sizes=\"auto, (max-width: 755px) 100vw, 755px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<ul class=\"wp-block-list\">\n<li>We achieved\u00a0<strong>high robustness<\/strong>\u00a0of this complex simulation chain<\/li>\n\n\n\n<li>The optimization using 13 parameters in a&nbsp;<strong>few design cycles<\/strong>&nbsp;(less than 50 simulations of the whole pump performance)<\/li>\n\n\n\n<li>The difficulties of optimizing with the&nbsp;<strong>vibration modes<\/strong>&nbsp;introduced a strong local minimum in the design space that could only be solved thanks to our extremely powerful optimization technique.<\/li>\n\n\n\n<li><strong>The efficiency is increased from 86.4 % to 88.5 %<\/strong>&nbsp;while respecting 30 mechanical constraints<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Pump Multi-Disciplinary Optimization In this application, the goal is to perform the optimization of a radial pump. The goal is to modify 13 parameters of the geometry to increase the pump&nbsp;efficiency&nbsp;while keeping the&nbsp;mechanical stresses&nbsp;below a maximum value and using constraints on the&nbsp;mechanical vibration mode&nbsp;of the pump.<\/p>\n","protected":false},"author":1,"featured_media":685,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"_themeisle_gutenberg_block_has_review":false,"_ti_tpc_template_sync":false,"_ti_tpc_template_id":"","footnotes":""},"categories":[11],"tags":[],"class_list":["post-681","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-article"],"_links":{"self":[{"href":"https:\/\/www.optimalcomputing.be\/index.php\/wp-json\/wp\/v2\/posts\/681","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.optimalcomputing.be\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.optimalcomputing.be\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.optimalcomputing.be\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.optimalcomputing.be\/index.php\/wp-json\/wp\/v2\/comments?post=681"}],"version-history":[{"count":31,"href":"https:\/\/www.optimalcomputing.be\/index.php\/wp-json\/wp\/v2\/posts\/681\/revisions"}],"predecessor-version":[{"id":1722,"href":"https:\/\/www.optimalcomputing.be\/index.php\/wp-json\/wp\/v2\/posts\/681\/revisions\/1722"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.optimalcomputing.be\/index.php\/wp-json\/wp\/v2\/media\/685"}],"wp:attachment":[{"href":"https:\/\/www.optimalcomputing.be\/index.php\/wp-json\/wp\/v2\/media?parent=681"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.optimalcomputing.be\/index.php\/wp-json\/wp\/v2\/categories?post=681"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.optimalcomputing.be\/index.php\/wp-json\/wp\/v2\/tags?post=681"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}